It's got some minor tweaks and two brand new features.
First is a correction factor. If you know for certain that your Wattson Energy Monitor is measuring incorrectly, you can use this to alter the readings. With a factor of 1, the value will remain as is.
With a factor of 1.01, Powometer will increase the readings it gets by 1%. With a factor of 1.1, it will increase it by 10%. The same applies to the negative. If you add a factor of -1.1, it will reduce you readings (Not your actual bill!) by 10%. Valid values are -1.99999 through to +1.99999. You cannot have zero as a factor.
Warning: Altering this value saves the readings as the new value and cannot be undone. Be sure you know the correct value before changing it. If you are uncertain, rather leave it as it is. They are not that incorrect.
Data Correction Feature:
If your Wattson Energy Monitor crashed or you had to turned off for a while, this feature is for you. It is for anyone who has suffered data loss from Holmes or Wattson.
At the click of a button it will find any "holes" in your data where you have missed readings. It will then create new readings to fill up these holes based on readings from similar times, and similar loads. It will then show you the readings it has created and allow you to edit these and tweak them. It shows them along side the closest real readings so you can see how accurate it is.
Once you are happy with the suggestions, you can save that back and from that point, everything looks more true.
The new version is live - download it and give it a whirl. You'll have to uninstall the old one and install this one.